Free shipping
Low Price
secure-order
View Cart

    Empire DVVK-4F Flexible Horizontal Fireplace Vent Kit - For Tahoe Fireplaces - DVVK-4F

    286.20
    List Price: $349.99
    Sale Price: $286.20
    You Save: $63.79 (18%)
    In Stock.
    * Usually Ships Same Business Day.
    • Flexible horizontal vent kit for fireplaces
    • Includes:
      • one (1) termination cap
      • one (1) wall thimble
      • collars
      • gear clamps
      • 4' of 4" x 7" flexible vent pipe
    • Compatible with all Tahoe Deluxe, 36" Tahoe Premium, and 36" Tahoe Luxury fireplaces
    See complete product details >>
    Popular Accessories for this Item
    Product Details
    Free Venting Design & Quote:
    Manufacturer: Empire
    Part Number: DVVK4F
    eFireplaceStore Item Number: CUI-DVVK4F
    UPC: 720968916198

    Features

    • Flexible horizontal vent kit for fireplaces
    • Includes:
      • one (1) termination cap
      • one (1) wall thimble
      • collars
      • gear clamps
      • 4' of 4" x 7" flexible vent pipe
    • Compatible with all Tahoe Deluxe, 36" Tahoe Premium, and 36" Tahoe Luxury fireplaces
    Make venting your Tahoe Direct Vent Fireplace as simple as possible with this Empire DVVK4F Flexible Horizontal Fireplace Vent Kit.
    Customer Questions & Answers
    By Jim from Fredericksburg, VA on July 10, 2015
    Do I need a heat shield for vinyl siding with this Empire DVVK-4F Flexible Horizontal Fireplace Vent Kit?
    By Will M. on July 10, 2015

    Answer:
    The design of the cap provides enough clearance for a siding shield to not be needed.

    By John from NL, Canada on October 15, 2014
    I have a Majestic DVR33 propane fireplace and I am having trouble finding a direct vent kit to fit it in my area. The fireplace was seldom used and is in like new condition. Can this kit be used to make it work with this fireplace? It is a 4" x 7" . I am attaching a picture to show the back of the fireplace. I am placing it in a corner, so the flex pipe would be perfect. If this kit won't work for me, do you have any suggestions?

    By eFireplaceStore on October 16, 2014

    Answer:
    There are slight differences between the Empire and Majestic piping that will not allow the two to be interchangeable. However, we do offer a very similar flex kit that could work for your model, which is the Monessen Up and Out Flex Vent Starter Kit - For Direct Vent Appliances that Require 4 Inch x 7 Inch Vent Pipe. Like the Empire kit, this Majestic kit will include the flexible piping, firestop, and termination needed to safely vent this unit.

    By William from Scott Depot, WV on July 30, 2014
    Does this vent kit work for the DVCD-32-FP3ON fireplace?
    By eFireplaceStore on July 30, 2014

    Answer:
    Yes. The DVVK-4F is listed for use with this model of Empire fireplace. It is an excellent choice for corner installations or for any install where a slight offset is required.

    By Darryl from Kansas City, MO on February 18, 2015
    I purchased an Empire medium loft fireplace from you and I want to use the DWK-4F kit to install it. The distance from the center of the vent pipe to the exterior stud wall is about 24.5 inches. Will this kit work? Is there anything else that I will need for venting? The wall material is 2x4 studs, OSB panels and then wood lap siding.
    By eFireplaceStore on February 18, 2015

    Answer:
    Based on your dimensions, this kit will indeed be just long enough to suit your application. The only other product needed is a sealant, such as the Rutland Seal It Right Direct Vent Appliance Sealant - 2.7 Ounce Tube to seal the tubing at the appliance and the termination.

    By Chad from Chicago, IL on June 14, 2016
    I have a Empire 36" Tahoe fireplace. I ordered the DVVK-4F flexible kit and then had to order flexible pipe extensions so i could reach my roof. My question is, i would like to come vertically out of my fireplace fifteen feet then turn ninety degrees horizontally and exit out the side of my house. I do have adequate clearance from combustibles and other requirements. I just want to make sure that what I am wanting to do is legit and if so, would this kit be suitable. If not suitable, what kit would you recommend?
    By Will M. on June 14, 2016

    Answer:
    For clarity, this is a horizontal vent kit that will have a termination cap that is only suitable for completely horizontal installations. For vertical applications where the pipe will exit through a pitched roof, this will not work.

    With that being said, the 36" Tahoe fireplaces are approved for use with flexible venting and this configuration will be acceptable so long as your horizontal run does not exceed 15 feet and all other termination clearances are followed where the horizontal termination cap will be positioned on your exterior wall.

    By Tim from Long Island, NY on September 6, 2014
    Do you need a siding standoff for this product as well?
    By eFireplaceStore on September 8, 2014

    Answer:
    This particular kit includes the standoff as an integral component of the termination. As such, an additional standoff is not required.

    By Shane from IA on November 11, 2014
    What part number is for the vinyl siding standoff for this kit?
    By eFireplaceStore on November 11, 2014

    Answer:
    The manufacturer does not list a vinyl siding standoff for this kit, as the standoff distance normally provided by such an item is actually built into the design of the cap.

    By Jorge from Pittsburgh, PA on October 2, 2014
    I recently purchased the "Empire Loft See-Through Direct Vent Gas Fireplace with RF Controls and Decorative Surround - 36 Inch" from you and want to know if the "Empire DVVK-4F Flexible Horizontal Fireplace Vent Kit" is the right venting choice for my particular case. I attached a couple of pictures from the blueprints of the house, indicating the location of the fireplace and of the termination cap. The termination cap will be 2" away from a stone wall, but will be mounted on a vinyl siding wall. Will this work?
    By Chris C. on October 2, 2014

    Answer:
    From the diagrams you have provided, I do indeed believe that this kit will work with the clearances required. It was a pleasure discussing the installation with you, and please let me know if you have additional questions or concerns regarding the installation.

    Customer Reviews
    Empire DVVK-4F Flexible Horizontal Fireplace Vent Kit - For Tahoe Fireplaces - DVVK-4F ( 286.2 )
    4 out of 5 Stars based on 1 review(s) - sorted by Most Helpful Customer Reviews

    Relatively easy to install.
    By
    JK
    from CENTERon
    January 26, 2016
    I would recommend this item to a friend.
    As the "headline" stated this items was relatively easy to install. The inside ducting was a bit tight for the outside "wall cap" connection. Make sure to "dry fit" all the items before assembly, and make the necessary adjustments.




    test
    +

    Let Our Experts Design
    Your Venting System

    +

    Find the Right Gas Logs
    For Your Fireplace

    Sign-up for our Email!
    Enter your email for new arrivals and special offers.