Home Chimney Pipe Vent Termination and Terminals
Napoleon Direct Vent Gas Stove Wall Terminal Kit

Napoleon Direct Vent Gas Stove Wall Terminal Kit

Write a Review
$663
85
Was $730.24
Save $66.39 (9%)
countdown clock icon
HURRY! Deal ends in 11h 32m 28s
Qty: 1

Only 2 left in stock — order soon

Ships same business day

Have questions?

Our NFI-certified experts are here to help!
Chat with us Chat With Us
Email your question Send a Message
Call us at 800-203-1642 Call 1-800-203-1642

Product Details

Manufacturer: Napoleon
Napoleon Part Numbers: GD-175
Item Number: NPL-GD-175
UPC: 629169009923
This gas stove terminal kit is for a direct vent gas stove. The gas stove terminal kit is made is made by Napoleon and is to be used on Napoleon products. The gas stove terminal kit includes everything you need for an install including one (1) 7" vent termination, one (1) 28" to 54" adjustable vent pipe, one (1) 24" vent pipe, one (1) 90? elbow, one (1) 10' x 4" flexible aluminum vent pipe with spacers, one (1) fire stop, one (1) black trim collar, and three (3) decorative metallic black bands.

Customer Q&A with Product Specialists

Jim C. from Wiscasset, ME. asked:
Is there any insulation surrounding the vent pipe between the wall, or does there need to be?
Is there any insulation surrounding the vent pipe between the wall, or does there need to be?
No, there is no insulation around the vent pipe where it passes through the wall, nor should any be added. Napoleon requires an open air space between the vent pipe and any combustible framing, and this space must remain empty. Installation manuals for Napoleon direct vent gas stoves using this kit explicitly state not to fill the space between the vent pipe and the enclosure with any material, including insulation or combustibles, and to always maintain specified clearances around the venting and firestop systems. Loose insulation or other materials in contact with the vent pipe pose a fire hazard.

The firestop included in the Napoleon Direct Vent Gas Stove Wall Terminal Kit manages the wall penetration. The opening in the exterior wall is cut and framed to accommodate the firestop assembly. Once dry-fitted, the brackets on the rear surface should rest against the inside surface of the horizontal framing. The firestop and black trim collar then seal the wall cavity, preventing insulation and other loose materials from entering the air space around the pipe.

The specific minimum air space required is detailed in the installation manual for your particular stove model. As a general reference, the Napoleon GDS20 installation manual specifies a minimum of 1 inch clearance on the sides and bottom, and 2 inches at the top of the vent pipe for horizontal runs.

Napoleon does mention optional insulation for vent runs passing through unheated spaces like attics, garages, or crawl spaces. This optional insulation, wrapped in a protective sleeve, is used to reduce condensation and is never packed into the clearance space at the wall.
Answered by: Nevins P. on Aug 10, 2026

Helpful?

0
Brian from NY asked:
If I start at the stove with 4 inch flex pipe, what do I do when I get to the termination box and have more flex than I need to complete the job? Do I cut it? What do you use if you have to cut it?
If I start at the stove with 4 inch flex pipe, what do I do when I get to the termination box and have more flex than I need to complete the job? Do I cut it? What do you use if you have to cut it?
A fine-toothed hacksaw should be used to cut off the excess length.
Answered by: Will M.

Helpful?

0
Charlie from Cordova asked:
Is this pipe painted black? Are the flex length able to be used in conjunction with the rigid pieces?
Is this pipe painted black? Are the flex length able to be used in conjunction with the rigid pieces?

Helpful?

0
Showing 3 of 3 Questions and Answers
Ask a Question