Home Fireplace Replacement Parts & Accessories Heat Management
Majestic Passive Heat Kit Starting Collar

Majestic Passive Heat Kit Starting Collar

Write a Review
$289.00
Was $359.99
Save $70.99 (20%)
countdown clock icon
HURRY! Deal ends in 11h 32m 28s
Qty: 1

Only 9 left in stock — order soon

Ships same business day

Have questions?

Our NFI-certified experts are here to help!
Chat with us Chat With Us
Email your question Send a Message
Call us at 800-203-1642 Call 1-800-203-1642

Product Details

Manufacturer: Majestic
Majestic Part Numbers: PH-MR
Item Number: MAJ-PH-MR
UPC: 652174970278
The Majestic Passive Heat Kit Starting Collar is a neat way to get your non-ducted passive heat system up and running. This kit comes with everything you'll need to make your setup work like a charm, including four cool passive heat templates, two handy passive heat adapters, two rear covers, and one front cover. You'll want to make sure you've got a side or front trim kit ready, or an open-top chase, to get this going. It's a straightforward solution that helps you achieve that cozy warmth you're looking for.

Compare This Product Line's Sizes and Options

Majestic Heat Management
Model Size Price
Majestic Passive Heat Kit for Side Discharge — $114.00
Majestic Passive Heat Kit Starting Collar — $289.00
Majestic 36 Inch Passive Heat Vent Trim Kit For Front Discharge 36 Inches $229.00
Majestic 42 Inch Passive Heat Vent Trim Kit For Front Discharge 42 Inches $229.00

Customer Q&A with Product Specialists

Mark W. from TX asked:
Is the page's statement that the kit requires a side or front trim kit or an open-top chase accurate? If I am using ducting to move heat into the room, what are the rear and front covers for?
Is the page's statement that the kit requires a side or front trim kit or an open-top chase accurate? If I am using ducting to move heat into the room, what are the rear and front covers for?
It depends on how the kit is finished, and our product page overstates the requirement for front discharge. Per the manufacturer's PH-MR installation instructions, a side discharge installation requires the PH-SIDETRIM register cover kit to complete the installation. For a front discharge installation, the PH-FRTTRIM-36 or PH-FRTTRIM-42 trim kit is an optional finishing method, and other standard finishing methods may be used. An open-top discharge uses the open chase instead.

The PH-MR is a non-ducted passive heat system. The manual describes it as conveying warm air from the fireplace into the same room through one front discharge slot, two side discharge registers, or an open top. The covers in the kit fit on the two passive heat adapters. The only instruction the manual gives about the covers is to remove and discard them when adding an optional Heat-Zone-Gas or Heat-Out-Gas kit. In that case, attach the kit venting directly on top of the adapter. The venting must not extend past the rib on the adapter and must not block the adapter's holes, or the chase can overheat. Check your fireplace's own installation manual to see which heat management kits are approved for it.
Answered by: Tyler M. on Nov 10, 2026

Helpful?

0
Showing 1 of 1 Questions and Answers